RPV-I&S
POWERED VENT GAS WATER HEATER
For your family’s comfort, safety and convenience we recommend
water heaters to be installed and serviced by a plumbing
professional.
TABLE OF CONTENTS
GENERAL INFORMATION............................................................1
INSTALLATION........................................................................2
Locating The Water Heater ................................................2
Minimum Clearances ..........................................................3
Venting ..............................................................................3
Specifications for
48 Gal, 65,000 BTU input (189.3 L, 19.1 kW/Hr)
65 Gal, 65,000 BTU input (246.1 L, 19.1 kW/Hr)
75 Gal, 76,000 BTU input (283.9 L, 22.3 kW/Hr) .............4
Specifications for
40 Gal, 40,000 BTU input (151.4 L, 11.7 kW/Hr)
48 Gal, 40,000 BTU input (189.3 L, 11.7 kW/Hr) .............5
Combustion Air Supply..............................................................7
Water Connections ....................................................................8
Gas Connections........................................................................9
Electrical Connections................................................................9
Wiring Diagram for
48 Gal, 65,000 BTU input (189.3 L, 19.1 kW/Hr)
65 Gal, 65,000 BTU input (246.1 L, 19.1 kW/Hr)
75 Gal, 76,000 BTU input (283.9 L, 22.3 kW/Hr) .............10
Wiring Diagram for
40 Gal, 40,000 BTU input (151.4 L, 11.7 kW/Hr)
48 Gal, 40,000 BTU input (189.3 L, 11.7 kW/Hr) .............11
GENERAL OPERATION................................................................9
Lighting and Shutdown Instructions.....................................12
Thermostat Adjustment .........................................................12
Burner Flame Check................................................................12
MAINTENANCE ...........................................................................13
INSTALLATION INSTRUCTIONS FOR POTABLE WATER AND
SPACE HEATING .........................................................................14
VENT PIPE PREPARATION AND JOINING ....................................14
GENERAL INFORMATION
This gas-fired water heater’s design is certified by CSA International under the
American National Standard Z21.10.1 - (as indicated on the rating plate) and
CSA 4.1-M - (as indicated on the rating plate).
This water heater must be installed in accordance with local codes or, in the
absence of local codes, the National Fuel Gas Code, ANSI Z223.1-Latest Edition)
and/or in Canada CAN/CGA B149 Installation Codes (Latest Editions). The
warranty for this water heater is in effect only when the water heater is
installed, adjusted, and operated in accordance with these Installation and
Operating Instructions. The manufacturer will not be held liable for any damage
resulting from alteration and/or failure to comply with these instructions.
This water heater is not design certified for installation in a mobile home. Such
an installation may create a hazardous condition and will nullify the warranty.
Do not use this appliance if any part has been submerged in water. You should
contact a qualified service technician to inspect the appliance and to replace
any part of the control system including the combination gas control which has
been submerged in water.
Make sure that you check the rating plate and combination gas control on the
water heater to be certain that the type of gas being supplied corresponds with
the marking on the rating plate and combination gas control.
A sacrificial anode is used to extend tank life. The removal of this anode, for
any reason, will nullify the warranty. In areas where water is unusually active,
an odor may occur at the hot water faucet due to a reaction between the
sacrificial anode and the impurities in the water. If this should happen, an
alternative anode may be purchased from the supplier that installed this water
heater. This will minimize the odor while protecting the tank. Additionally, the
water heater should be flushed with appropriate dissolvers to eliminate any
bacteria.
INSTALLATION & SERVICE MANUAL
WARNING
If the information in these instructions is not followed exactly,
a fire or explosion may result causing property damage, personal
injury or death.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable, combustible, or
corrosive vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any telephone
in your building.
Immediately call your gas supplier from a neighbor’s
telephone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a qualified installer,
service agency or the gas supplier.
CAUTION
Incorrect operation of this appliance may create a hazard to
life and property and will nullify the warranty.
DANGER
Do not store or use gasoline or other flammable, combustible,
or corrosive vapors and liquids in the vicinity of this or any
other appliance.
IMPORTANT
Before proceeding, please inspect the water heater and components for
possible damage. DO NOT install any damaged components. If damage is
evident then please contact the supplier where the water heater was
purchased or the manufacturer listed on the rating plate for replacement
parts.
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1

1RPV-I&SPOWERED VENT GAS WATER HEATERFor your family’s comfort, safety and convenience we recommendwater heaters to be installed and serviced by a

Seite 2

10RPV-I&S Figure 11

Seite 3 - Figure 1

11RPV-I&S Figure 12

Seite 4 - Figure 4

12RPV-I&STHERMOSTAT ADJUSTMENTThe thermostat dial is adjusted to approximately 120°F when shipped from thefactory. When adjusting the thermostat,

Seite 5 - Figure 5

13RPV-I&SMAINTENANCEThe following maintenance should be performed by a qualified service technicianat the minimum periodic intervals suggested bel

Seite 6 - IMPORTANT

14RPV-I&STHE FOLLOWING INSTRUCTIONS ARE FOR INSTALLATION OF:GAS WATER HEATERS SUITABLE FOR WATER (POTABLE) HEATING AND SPACE HEATING1. All piping

Seite 7

15RPV-I&SVENT PIPE PREPARATION AND JOININGMost failures in PVC, CPVC or ABS systems result from improper preparation andjoining of pipe and fittin

Seite 8 - WARNING

16RPV-I&S Printed in USA

Seite 9

2RPV-I&SINSTALLATIONLocating The Water HeaterDO NOT install the water heater in any location where gasoline orflammable vapors are likely to be pr

Seite 10 - Figure 11

3RPV-I&S 76,000 BTU (283.9 L - 22.3 kW/Hr) models. Part II will coverventing specifications for 40 Gal - 40,000 BTU (151.4 L - 11.7 kW/Hr) and 48

Seite 11 - Figure 12

4RPV-I&Sdiameter PVC pipe. When venting with 4" (10.2 cm) PVC, use a 4" (10.2 cm) to3" (7.6 cm) reducer to exit through the buildin

Seite 12 - Figure 13

5RPV-I&SNOTE: For installations requiring both horizontal and vertical runs,the following rule must be followed: Total number of feet of straightp

Seite 13

6RPV-I&SNOTE: When using 3" (7.6 cm) PVC, use a 3" (7.6 cm) to 2" (5.1 cm)reducer and exit the building wall with 2" (5.1 cm)

Seite 14

7RPV-I&SNOTE: For installations requiring both horizontal and vertical runs,the following rule must be followed: Total number of feet of straightp

Seite 15

8RPV-I&S1. When directly communicating with the outdoors, each opening must havea minimum free area of 1 square inch per 4000 BTU (6.5 cm2/1.2 kw)

Seite 16 - Printed in USA

9RPV-I&SGAS CONNECTIONSThe gas supply lines must meet all requirements of the National Fuel Gas CodeANSI Z223.1-(Latest Edition) and/or in Canada

Kommentare zu diesen Handbüchern